Applications
Sigma 700 and 701 are force tensiometers used for the determination of:
- Surface tension
- Interfacial tension
- Critical micelle concentration
- Dynamic contact angle
- Surface free energy
- Powder wettability
- Adsorption
- Wettability
- Cleanliness
- Sedimentation
- Density
Measuring with Sigma 700/701
Available measurements:
- Static surface tension
- Static interfacial tension
- Automatic critical micelle concentration
- Dynamic contact angle
- Surface free energy
- Powder wettability
- Density
- Sedimentation
Sigma 700 and 701 outstanding versatility makes them suitable for research and development, industrial quality control, routine measurements and even educational use. It features full computer control and high level of automation. Special attention has been paid to the ergonomic and user-friendly design.
Sigma 700/701 force tensiometers come with the OneAttension software for unparalleled performance and usability:
- Fully automatic measurements avoids user dependant variation and saves time
- Select readymade experiment recipes or create custom programs for quick and repeatable operations
- Programmable probe and sample immersion and withdrawal cycle(s)
- Step by step powder protocol for simple powder wettability measurement
- Fully automatic CMC measurement
OneAttension is an all-inclusive software enabling immediate access to all measurement capabilities with no need to purchase and install separate software modules. It features an intuitive user interface, live analysis, configurable user groups and accounts and a preset liquid database. Any datapoints or groups of datapoints can be selected, transformed, plotted and analyzed. Data can easily be exported. In-depth analysis is now just a matter of seconds.
Accessory modules for dispensers and temperature or pH control can be easily mounted into the measuring unit. In addition, special probes are available for density, wettability and tensiometry measurements as well as holders for fiber and plate studies. Two dispensers can be used simultaneously for critical micelle concentration (CMC) measurements, allowing a full CMC curve to be obtained in one measurement.
Because of its wide weight range and autocalibrating microbalance, the Sigma 700 is well suited for dynamic contact angle measurements of large and heavy solid and powder samples. Very similar to Sigma 700, Sigma 701 is also a multipurpose tensiometer but equipped with a different microbalance optimized for a different range of applications. Sigma 701 can measure in a much more narrow weight range but with improved sensitivity, optimized for fiber measurements.
Balance specifications
| |
Sigma 700 |
Sigma 701 |
| Measuring range |
1...2000 mN/m |
1...1000 mN/m |
| Displayed resolution |
0.001 mN/m |
0.001 mN/m |
| Maximum load |
210 g |
5 g |
| Weighing resolution |
0.01 mg |
0.005 mg |
| Force resolution |
0.1 µN |
0.05 µN |
| Contact angle range |
0...180° |
0...180° |
| Contact angle resolution |
0.01° |
0.01° |
| Calibration & locking |
Automatic |
Manual |
Measuring unit specifications
| |
Sigma 700 |
Sigma 701 |
| Sample stage |
Motorized |
Motorized |
| Sample stage speed |
0.01...500 mm/min |
0.01...500 mm/min |
| Stage positioning resolution |
0.016 µm |
0.016 µm |
| Dimensions |
L33,3 xW 24,4 x H62 cm |
L33,3 xW 24,4 x H62 cm |
| Weight |
16,3 Kg |
13 Kg |
| Power supply |
85...264 VAC |
85...264 VAC |
| Frequency |
47...440 Hz |
47...440 Hz |
Recommended system requirements
1GHz processor, 1GB MB RAM, 40 GB hard disk drive (20GB free), 1 USB port.
Accessories such as water bath and liquid dispenser may require a free RS-232 port.
Operating system requirements
Windows 7 (32 or 64 bit), Windows Vista (32 bit), Windows XP SP3 (32 bit).
More information is available from the product catalogue. Accessories can be found here.
Specifications and appearances are subject to change without prior notice.