Applications
- De-greasing operations
-
Surface treatment bath control
-
De-inking and floatation
-
Cleaning bath monitoring
-
Environmental monitoring
Measuring with AL-20
AL-20 is designed for at-line sampling of process liquids and statistical process control. It is built for regular surface tension measurements. After each measurement, the operator can dose the process with chemical additives or water until the surface tension is at the desired level. Thus, AL-20 allows optimization of additive amounts, leading to reduced waste, economical savings and environmental benefit. AL-20 can also be used for manual determination of critical micelle concentration.
AL-20 is a robust, portable and standalone tensiometer ideal for at-line or in-lab use. It features one-button operations to measure, calibrate and clean the instrument, for unparalleled ease of use and simplicity. Results are obtained in 70 seconds and displayed on the large digital screen, making AL-20 the ideal solution for quick quality check and routine measurements. The data is stored in memory and can be uploaded to a computer for further analysis, using the provided AL-20 data collection software.
Measuring with OL-55
OL-55 is the on-line volumetric tensiometer developed for full and easy integration to a production line. Surface tension is continuously measured, and a constant feedback mechanism allows automatic dosage adjustments. OL-55 is equipped with a self cleaning filter for minimal maintenance. As an option, OL-55 can also be upgraded to monitor pH, temperature and conductivity, making it a versatile instrument in process liquids for optimal dosing of chemicals.
OL-55 rugged design qualifies for demanding factory applications. Fully automatic computer controlled operations limits the need for external intervention and human error. The advanced software enables continuous recording of surface tension, pH, temperature and conductivity, plotted in real-time. The data is stored on the computer hard drive for future analysis. Requiring minimal input and maintenance, OL-55 is the perfect solution for efficient control over operations, costs and quality.
Technical specifications
| |
AL-20 |
OL-55 |
Surface tension measuring range
|
20...73 mN/m
|
20...73 mN/m |
| Accuracy |
± 0.5 mN/m |
± 0.5 mN/m |
| Minimum sample volume |
25 ml |
- |
| Flow rate |
- |
18L / hour |
| Temperature range |
- |
15... 85 °C (option) |
| pH range |
- |
2...14 (option) |
| Conductivity measuring range |
- |
0...2,000,000 µS (option) |
| Self cleaning filter |
- |
100 μm (others by request) |
| Power supply |
100...240V |
100...240V |
| Frequency |
50...60Hz |
50...60Hz |
| Dimensions |
L 20 x W20 x H42,5 cm |
L 42,8 x W23,6 x H54,4 cm |
| Weight |
4,6kg |
26,5 Kg |
Recommended system requirements
2GHz processor, 2GB MB RAM, 100 GB hard disk drive (40GB free), 1280x1024 resolution,1 RS-232 Port
Minimum system requirements
1GHz processor, 512 MB RAM, 40 GB hard disk drive (20GB free), 1024x768 resolution
Operating system requirements
Windows 2000 SP4, Windows XP SP2 (32 bit), Windows Vista Home SP1,
Windows Vista Home Premium SP1, Windows Vista Ultimate (32 bit) SP1,
Vista Business SP1 (32bit).
More information is available from the product catalogue.
Specifications and appearances are subject to change without prior notice.
Biolin Scientific shall not be liable for any errors on this website.